Applications of X-ray Examination Technology
Hidden solder joint (ex BGA)
Densely packed solder joint (ex BGA) for which installation of test probe is difficult
Areas for which camera photography is difficult due to mirror surface
(ex, solder joint monitoring equipment following Reflow process)
Advantage: expedient examination (vs destructive examination)
 
Purposes of Usage
- Detection of defectiveness :
   Key examination items: bridging, open, insufficient, excess,
   missing balls, misregistration, package "popcorning",
- Analysis of error in procedure :
   Trend analysis: solder volume, solder joint shape
- Quality analysis
 
 
For effective examination

- X-ray image acquisition technology
- Understanding of technology of X-ray image analysis

 
Technology for acquisition of X-ray image (Solder Joint examination area)
 
  - Ffilm based X-ray Inspection
   Process is complex, need specialization,
   slow, Although high cost of image taking, one
   can obtain precision image.

Figure 46 X-ray Laminography
Images of CBGA Solder Joints
 
  - Ffilm based X-ray Inspection
   Process is complex, need specialization, slow, Although high cost of image taking,
   one can obtain precision image.
   
 
     

- Real time X-ray system
   Although the disadvantages of Film based
   technology has been overcome, there are
   problems of Voltage blooming and pincushion
   distortion
   → Overcome with Flat Detector technology,
   high cost

- Diverse range of sizes:
   desk top~10 M x 10 M

   Diverse range of voltages: several kV ~ several
   hundreds of kV

- What is the Voltage appropriate for BGA
  examination?

    Structure of copper thermal radiator
    requires Higher Voltage
    High-Sensitivity camera
    requires Lower Voltage

Figure 44 X-Ray Can Be Used to Detect BGA Package
"Popcorning" (PincushionDistortion)
Technologies for Analysis of Soldering Status
 
  >Transmission  

It=Io exp(-¥ìT), appears darker if the thickness of
the lead is thicker. Lines are expressed as points
without distinction of front from the back Collection
of cone shaped lines.

 
  >Scanning Acoustic Microscopy (SAM)
Ultrasound wave, examine by immersing in medium
(water, alcohol), 230 MHz → 25 μGap
a-SAM - point
b-SAM - line
c-SAM - surface
Effective in examination of void within under fill
 
  >Feeler Gage
Gap gauge, measurement of stand-off of rectangular corner, inaccurate
convenient, low cost
 
  >BGA Stand-off measurement
laser, contact sensor
reflow - uniformity,
0.75mm ball
0.60mm → 0.45 mm , after reflow
 
 

>Destructiveanalysis methods
From the perspective of solving
problem, destruction of samplebr

- Cross-sectioning

 Molded with resin ->presumption of
location   There are many
cases of accidental occurrence of
open and crack in the process of
examination.

- Dye Penetrant
   Observe by infiltrating with dye and
   fluorescent material (UV light)


A BGA inspection that is produced by XAVIS is a well made X-ray inspection. XAVIS’ BGA inspection is highly efficient and low priced equipment that can be used for hidden solder joint, densely packed solder joint for which installation of test probe is difficult and areas for which camera photography is difficult due to mirror surface. We put our efforts on producing our BGA inspection which does not cause the destructive examination. Xavis exports BGA inspection worldwidely, and our BGA inspection gives satisfaction to our customers. Check our website for more information of BGA inspection